The Atmospheric Electricity Group (ELAT) from CCST / INPE had developed an accurate methodology for cloud-to-ground lightning warning with one hour in advance for regions with less than 100 km2. Based on real-time total lightning data provided by lightning detection network, electrostatic field-mill measurements, IR satellite images, and weather radar images, cloud-to-ground lightning warnings are issued based on the probability of a thunderstorm to occur in a particular region. This approach is very attractive because for specific regions (like airports, soccer stadiums, oil refineries, mining, parks, etc.), the forecast based only on numerical models or radar images is not suitably accurate in time and/or spatial domains. The main purpose of issuing lightning warnings with some lead time is to protect human life from lightning threads while in outdoor activities. Main results are: less than 20% of false alarms, lead time of about 30 to 40min and warning total duration of about 02 to 03h. The paper also presents a comprehensive risk analysis of lighting threads for outdoor activities showing risk maps for different scenarios as a function of the time of exposure and level of protection. An example, a lightning warning system that combines total lightning data and numerical model simulations is also discussed illustrating how it can predict the occurrence of a severe storm in a particular region with a lead time of 30 min and thus help preventing human casualties.